The part numbers listed below are not the only cables available to the merchants, these numbers were gathered from TASQ Technologies, JR’s POS Depot, The Phoenix Group, and a few others.

Some terminals have the capability of uploading the images through the terminal with the aid of an application and therefore; not requiring a telephone line or Ethernet connected to the imager itself.

Ingenico iCT: The CAB350086A cable adapter is also required.
PAX 80: The 1000001866-A cable adapter is also required.
VeriFone Omni Vx520: The 08798-01-R USB-RS232 adapter will be required if PIN Pad is connected to the RS232 port.
Terminal Type Connector Description Part Number
Hypercom T4100
Modem Upload
3 Connections: RS-232 (Scanner Connection), RJ-14 ( Telephone Connection) and RS-232 (9-Pin Mini-DIN, Terminal Connection), cable length is 6 feet. Images upload through the MICR-Image's internal Modem via RJ-14 connection. 22410311 REV A
Hypercom T4200
Terminal Upload
2 Connections: RS-232 (Scanner Connection) and SERIAL (RJ-14, Terminal Connection). Images upload through the terminal via the RJ-14 connection. 22410320 REV A
Ingenico i-Series
Modem Upload
3 Connections: RS-232 (Scanner Connection), RJ-14 (Telephone Connection) and RS-232-2 (RJ-6, Terminal Connection). Images upload through the internal Modem via RJ-14 connection. 22410322 REV A
Ingenico i-Series
Ethernet Upload
3 Connections: RS-232 (Scanner Connection), RJ-45 (Ethernet Connection) and RS-232-2 (RJ-6, Terminal Connection), cable length is 2 feet. Images upload through the internal Network Interface Card (NIC) via RJ-45 connection. 22410321 REV A
Ingenico iCT-200 Series
Modem Upload
3 Connections: RS-232 (Scanner Connection), RJ-14 (Telephone Connection) and RS-232-2 (RJ-6, Terminal Connection). Images upload through the internal Modem via RJ-14 connection. 22410322 REV A
(See note below)
Ingenico iCT Series
Ethernet Upload
3 Connections: RS-232 (Scanner Connection), RJ-45 (Ethernet Connection) and RS-232-2 (RJ-6, Terminal Connection), cable length is 2 feet. Images upload through the internal Network Interface Card (NIC) via RJ-45 connection. 22410321 REV A
(See note below)
Nurit (all models)
Modem Upload
3 Connections: RS-232 (Scanner Connection), RJ-14 (Telephone Connection) and COM1/RS-232 (RJ-45, Terminal Connection), cable length is 2 feet. Images upload through the internal Modem via RJ-14 connection. 22410300 REV A
PAX80 RS-232 (Reader Connection) and COM (RS-232 DB-9 Female Connection), the cable is Gray in color and 9 feet long. 22410302 REV C
(See Note Below)
TechTrex
Modem Upload
3 Connections: RS-232 (Scanner Connection), RJ-14 (Telephone Connection) and PIN (RJ-14, Terminal Connection), cable length is 8 feet. Images upload through the internal Modem via RJ-14 connection. 22410323 REV A
TechTrex
Ethernet Upload
3 Connections: RS-232 (Scanner Connection), RJ-45 (Ethernet Connection) and PIN (RJ-14, Terminal Connection), cable length is 2 feet. Images upload through the internal Network Interface Card (NIC) via RJ-45 connection. 22410324 REV A
VeriFone Omni Series
 (Excluding 3200 Series)
Modem Upload
3 Connections: RS-232 (Scanner Connection), RJ-14 (Telephone Connection) and RS-232 (RJ-45, Terminal Connection), cable length is 8 feet. Images upload through the internal Modem via RJ-14 connection. 22410312 REV A
(See Note Below)
VeriFone Omni Series
 (Excluding 3200 Series)
Ethernet Upload
3 Connections: RS-232 (Scanner Connection), RJ-45 (Ethernet Connection) and RS-232 (RJ-45, Terminal Connection), cable length is 2 feet. Images upload through the internal Network Interface Card (NIC) via RJ-45 connection. 22410315 REV A
(See Note Below)
Virtual Terminal
Ethernet Upload
3 Connections: RS-232 (Scanner Connection), RJ-45 (Ethernet Connection) and COM1 (RS-232 DB9 Female PC Connection), cable length is 8 feet. Images upload through the internal Network Interface Card (NIC) via RJ-45 connection. 22410307 REV A


NOTE: ALL cable connections will be connected unless otherwise noted.
If there is a PIN Pad in use, plug the imager into the Bar Code Port.
If an application is installed to perform image uploading, the telephone line or Ethernet connection is not required, images will upload through the terminal via its connection.


Updated: 07/21/2017